Multiple analysing

News
First Trace Gas Analyzer to Simultaneously Measure CO, CO2, and H2O in Real-Time
The Picarro G1302 trace gas analyzer is the first turnkey instrument capable of simultaneously measuring CO and CO2 with high precision, in real-time, and with minimal calibration required. This makes it suitable for remotely operated (unattended) GHG monitoring applications, including tall-tower measurements as well as for research and reference laboratory use, providing both superior performance and lower overall costs than previous technologies. In particular, the G1302 delivers measurement precision down to 2 ppbv for CO, 50 ppbv for CO2. Based on Picarro’s proven wavelength-scanned cavity ring down spectroscopy (WS-CRDS) technology, this new analyzer also provides quantitative data on H2O concentration levels.

In field CO2 monitoring applications, CO is commonly used as an anthropogenic CO2 emission indicator as well as a method to co-identify CO and CO2 plumes of incendiary origin, as opposed to natural origin from soils, etc. Unfortunately, traditional technologies require frequent calibration and maintenance, as well as the use of a different analyzer for each gas species. Because the Picarro G1302 analyzer is based on WS-CRDS technology, crosstalk between the detected species and other atmospheric gas constituents is avoided, allowing this new analyzer to simultaneously monitor multiple species, with superior precision than older single-gas methods.

Mike Woelk, CEO of Picarro, adds, “Our company is committed to supporting air and atmospheric monitoring applications with trace gas analyzers that deliver superior performance and simplicity of use. But we also recognize that the diverse needs of some of these applications must be supported with analyzers optimized for their specific requirements. Our new G1302 analyzer is a perfect example of this philosophy, targeting the scientists who need to simultaneously monitor a particular combination of target gases – CO, CO2 and H2O – where there was previously no single solution to match this need.”

×
Search the news archive

To close this popup you can press escape or click the close icon.
Logo
×
Logo
×
Register - Step 1

You may choose to subscribe to the Silicon Semiconductor Magazine, the Silicon Semiconductor Newsletter, or both. You may also request additional information if required, before submitting your application.


Please subscribe me to:

 

You chose the industry type of "Other"

Please enter the industry that you work in:
Please enter the industry that you work in: